A patient who had previously undergone hip hemiarthroplasty presented with dislocation of the prosthesis and a concomitant fracture of the anterior wall of the acetabulum.
Due to the complex nature of the case, the hemiarthroplasty was converted to a total hip replacement.
A peripheral self-locking acetabular cup was used for acetabular reconstruction, with the aim of achieving strong primary stability of the prosthesis.
At the same time, the Modular Dual Mobility (MDM) system was selected, as it offers increased joint stability and helps to reduce the risk of post-operative dislocation, particularly in complex revision procedures.
ORIS Orthopaedic Centre offers specialist diagnosis and treatment of musculoskeletal conditions, with the aim of restoring mobility and improving the quality of life of every patient.
Για να σας προσφέρουμε την καλύτερη δυνατή εμπειρία, χρησιμοποιούμε τεχνολογίες όπως τα cookies για την αποθήκευση ή/και την πρόσβαση σε πληροφορίες της συσκευής σας. Η συγκατάθεσή σας για τη χρήση αυτών των τεχνολογιών θα μας επιτρέψει να επεξεργαζόμαστε δεδομένα όπως η συμπεριφορά περιήγησής σας ή μοναδικοί αναγνωριστικοί κωδικοί σε αυτόν τον ιστότοπο. Η μη συγκατάθεσή σας ή η ανάκληση της συγκατάθεσής σας ενδέχεται να επηρεάσει αρνητικά ορισμένες δυνατότητες και λειτουργίες.